Before testing photovoltaic solar panels, you need to understand the test conditions: test principles, test tools, test standards (environment), and test parameters. The following is a detailed description for everyone.
Test principle
The working principle of the test system is: when the flash shines on the battery under test, the electronic load is used to control the current change in the solar cell, and the voltage and current on the battery’s volt-ampere characteristic curve, temperature, light intensity, and test data It is sent to a microcomputer for processing, display and printing.
Test tools
Solar cell module tester, AAA grade solar cell module tester
Test standards (environment)
Irradiance 1000 W / m2, ambient temperature 25 ° C, AM = 1.5; power tolerance range: ± 3%).
Test parameters
Maximum measurable component battery size: 1100mm * 2000mm
Light source: high-energy pulsed xenon lamp
Adjustable range of light intensity: 70—120W / C㎡
Light pipe life: ≥300000 times
Light uniformity: ± 3%
Measuring range and accuracy: voltage 0 ~ 30V ± 0.1% 0 ~ 60V ± 0.1%
Current 0 ~ 2A ± 0.1% 0 ~ 20A ± 0.1%
Measurement error: ≤2%
Repeated measurement error: ± 1%
Standard system configuration: horizontal test bench + PC + special test software
Power requirements: 220V / 50Hz / 2KW
Weight: 320Kg
Dimensions: 850mm * 1500mm * 2460mm